WCCOAtoolCMactivation - License request for an empty station

  • On the Offline Computer:
    1. Create a new container on the offline computer:
      cmu32 -i --file wiccoa_install_dir\data\license\ETM_pc_-_A_Siemens_Company.WibuCmLif
      by using a license template (LIF) from the WinCC OA setup.
    2. Create a license request (cmu32):
       cmu32 -c 6000802 -f 130-XXXXXXXXX.WibuCmRaC --serial 130-XXXXXXXXX.
    3. Copy the license request file WibuCmRac to a flash drive or external hard disk.
    4. Transfer the license request file to the activation station (online computer).
  • On the Online Computer:
    1. Activate the license
      WCCOAtoolCMactivation -activate -context 130-XXXXXXXXX.WibuCmRaC -serial 130-XXXXXXXXX -update 130-YYYYYYYYY.WibuCmRaU
                                      https://license-portal.example.com/12345/gateways XXXXX-XXXXX-XXXXX-XXXXX-XXXXX.
    2. Save the license update file WibuCmRaU to a flash drive or external hard disk. Transfer the WibuCmRaU to the offline computer.
  • On the Offline Computer:
    1. Import the license update file:
      cmu32 --import --file <absoluteFilepath>/130-XXXXXXXXX.WibuCmRaU
    2. Create a receipt and confirm:
      cmu32 -c 6000802 -f 130-XXXXXXXXX.WibuCmRaC --serial 130-XXXXXXXXX
    3. Copy the 130-AAAAAAAAA.WibuCmRaC file to a flash drive or external hard disk. Transfer the license request file to the activation station (online computer).
  • On the Online computer:
    1. Confirm via:
      WCCOAtoolCMactivation -confirm -serial 130-XXXXXXXXX -context 130-ZZZZZZZZZ.WibuCmRaC https://license-portal.example.com/12345/gateways
                                      YYYYY-YYYYY-YYYYY-YYYYY-YYYYY